-40%

DPS3003 Constant Voltage current Step-down Programmable Power Supply module NEW

$ 14.25

Availability: 106 in stock
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • MPN: Does Not Apply
  • Item must be returned within: 60 Days
  • Return shipping will be paid by: Buyer
  • Brand: Unbranded/Generic
  • Condition: New
  • UPC: Does Not Apply

    Description

    DPS3003 Constant Voltage current Step-down Programmable Power Supply module NEW
    General Information
    The constant voltage and constant current programmable control power supply module put the collection of analog integration and digital control functions in one. Its adjustable output voltage range is 0-
    32.00V
    , step by 0.01V. Its adjustable output current range is 0
    -3.000A,
    step by 0.001A. This module has power-down stored function and can store 10 groups preset value. And it also has the function of extracting quickly two groups stored value. Compared with the traditional analog power supply, it is more convenient to quickly extract the voltage or current required. LCD display on the module has the function digital voltmeter and ammeter. You can view the preset voltage, input voltage, output voltage, the preset current, output current, output power, etc. on the output state remind area, you can see that output opens or not, the state of constant voltage and constant current, output is normal or not, the key is locked or not, and the current data groups that is being used. On the setting data interface, you can adjust overvoltage value, overcurrent value, over-power value, data set and LCD brightness. This module has many advantages, small size, advanced function, good visual effect, high operability, high-precision, being used independently, being inset into the device and been widely applied.
    Technical parameters
    Input voltage range:  6.00-40.00V                                Output voltage range:  0V-32.00V
    Output current: 0-3.000A                                               Output power range: 0-96W
    Product Weight: about 90g                                            Product Dimension: 79*43*41(mm) (L*W*H)
    Open size:  71mm*39mm                                               Output voltage resolution: 0.01V
    Output current resolution: 0.001A                                Output Voltage accuracy: ± (0.5% + 1 digits)
    Output Current accuracy: ± (0.5% + 2 digit)
    NOTE: You must make sure that the input voltage is 1.1 times higher than output voltage. Under large current circumstances, pay attention to heat elimination.
    Connection description
    IN+: Input positive                      IN-: Input negative:
    OUT+: Output positive:              OUT-: Output negative
    Note: Input voltage range is DC 6-40V and 40v is the limit voltage; please leave a room to use. Or else it will be burnt. The input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has reverse connection protection and output short circuit protection, you can muse be in strict accordance with connection description to connect. If you connect the supply power with output, the module will be burnt.
    Panel description
    1-Voltage setting/Page up to choose/Shortcut extract M1 data group
    2-Data setting/ Extract value of the specified data group/Store value into the specified data group
    3-Current setting/Page Down to choose/Shortcut extract M2 data group
    4-1.44 inch color LCD screen
    5-Coding potentiometer/Data adjustment/Lock all buttons
    6-Open or close output
    Display interface description
    7-The preset value of output voltage
    8- The actual value of output voltage
    9-The actual value of output current
    10-The actual value of output power
    11-The actual value of input voltage
    12-The preset value of output current
    13-Key lock or unlock prompt
    14-Output normal or not prompt
    15-Constant voltage and constant current status prompt
    16-Data set prompt
    17-Open or close output prompt
    18-Preset output voltage
    19-Preset output current
    20-Preset over- voltage
    21-Preset over-current
    22-Preset over-power
    23-Preset screen brightness
    24-Preset data set
    25-The actual value of output voltage and output current
    Operating instructions
    When connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lock icon, abnormal output status icon, constant voltage and constant current icon, data set tip icon and opening or closing output icon.
    Set the output voltage and output current on the main interface.
    Press V/↑key shortly, you can enter into voltage setting status. Then press the coding potentiometer, and then enter to adjust the numerical value. Press coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clockwise rotation to increase the numerical value; Turn by counterclockwise to decrease the numerical value. If you want to exit adjusting the numerical value, press shortly V/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too.  You can press A/↓to set the output current by the same way.
    Set the data on the data setting interface
    On the main interface, you can press SET key shortly to enter into data setting interface. On the data setting interface, press shortly V/↑or A/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface .
    Set the protection value.
    Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed. And then press shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, press shortly SET key.
    Adjust the brightness of screen.
    Page up or page down to B-LED, and then press shortly the coding potentiometer to enter into the status of adjusting the brightness of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, press shortly SET key. There are six brightness levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.
    Data setting and store the specified data group.
    Page up or page down to M-PRE, and then press shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then press the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, press shortly SET key. Then press shortly V/↑or A/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep pressing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can press shortly SET key back to the main interface.
    Set default boot open or close output
    Page up or page down to S-INI, and then press shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.
    Function description.
    Open or close the output
    .
    You can press ON/OFF key to open or close the output on any interface.
    Lock the button to avoid wrong operation.
    On the any interface, you can keep pressing coding potentiometer more than 2s, all buttons are locked. You can see the key lock icon on the right of screen. If you want to unlock all buttons, keep pressing coding potentiometer more than 2s, all buttons are unlocked. The key unlock icon will be displayed on the right of screen.
    M0-M9 ten groups data group
    M0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.
    Extract Shortcut storage data group M1 or M2.
    On the main interface, keep pressing V/↑or A/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quickly. In the same time the corresponding data group number will displayed on the right of the screen.
    Extract the specified data group.
    On the main interface, keep pressing SET key more than 2s, the sequence number of data group will be displayed on the right of the screen, you can turn coding potentiometer to choose data group you need. And then press shortly SET key, you can extract the specified data group you need.
    Payment
    Shipping
    Refund
    Payment
    We only accept payment through Paypal.
    Items will go to post within 1-2 business days after payment confirmed.
    Shipping
    1. We ship to Worldwide.
    2. We only ship to confirmed PAYPAL address; your PAYPAL address must match your Shipping address.
    3. Any non-received items caused by invalid address registered on PayPal are not in our full refund or replacement policy. Shipping fee has including the local handing and packaging fee.
    4. All the items will be shipping within 1-2 working days after receiving the payment, except some holidays.
    5. We will not be responsible for any custom delay or tax, because transit time is highly depended and provided by postal Service.
    6. If you have any problem, please contact us via message, we will reply message within 1-2 working days, please wait for patient.
    Refund
    If you can't receive the product within 2 months (60 days), please contact with us,we promise to payback 100% of your money.
    We ensure our products work normally before post.If the products is broken before arrival to you,all you should do is taking a photo to show us our broken product.We promise to payback 100% of your money.
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
    On Aug-03-17 at 20:56:46 PDT, seller added the following information: